Sirui-Tech logo Sirui-Tech

Charger Magnetics Are Sized by the Charge Profile

A battery charger is not a constant load: it runs at constant current while the battery is deeply discharged, then at constant voltage as it approaches full, then at a trickle. A transformer or inductor designed for the nameplate current will be wrong at one or both ends of that profile, and the most common symptom is a charger that runs cool at full load and hot at the end of charge, or vice versa.

For buyers, the specification must include the charge profile, not just the output rating.

Topologies and Their Magnetics

Common charger architectures and the magnetic components involved
Architecture Power range Magnetics Key design point
Linear (50/60 Hz transformer) Up to ~200 W Mains transformer Size and heat at low cost; efficiency 50–65 %
Flyback 5–150 W Flyback transformer + input EMI choke Leakage inductance snubbing and core gap
LLC / forward 100–1,000 W HF transformer + resonant inductor Resonant tank design across the charge range
Buck / boost stage Any Output inductor Current ripple and saturation at CC and CV

The CC and CV Ends Behave Differently

At the constant-current end, the output inductor carries maximum DC current with moderate ripple, so saturation and copper loss dominate. At the constant-voltage end, current falls but the switching behaviour often becomes discontinuous or the duty cycle leaves the resonant range, and core loss can rise while copper loss falls. A design verified only at full load can therefore be at its thermal worst at 20 % load.

Practical approach: specify loss at three operating points — the CC maximum, the CV start, and the trickle current — and require the supplier to state which one is thermally limiting. It is frequently not the one the buyer assumed.

Isolation and Safety for Chargers

Chargers for consumer batteries usually require reinforced insulation between mains and output, with the output classified as SELV. That drives the same barrier questions as any offline converter: triple insulated wire or a taped barrier, a defined creepage, and a hipot test at 3,000 V AC for one minute on the type test. For chargers with a metal enclosure or a battery pack connector that the user can touch, the creepage on the connector side must also be reviewed, not only inside the transformer.

Thermal Design for Sealed Chargers

Chargers are often sealed and potted, sometimes fan-less, with internal ambient 20–30 K above room temperature. Under those conditions, the transformer’s hotspot sets the whole product’s reliability. Specifying Class F or H insulation and requiring the temperature rise at the sealed ambient — not open air — is the difference between a 5-year and a 1-year product.

What to Specify

Related reading

We size charger magnetics against the full CC-CV profile and report loss at the three points that matter, with the thermally limiting condition identified. Send the battery chemistry, charge profile, and enclosure conditions to sales@sirui-tech.com.