UV Ballasts Are Leakage-Transformer Applications

Germicidal UV lamps and medium-pressure UV curing lamps need a ballast that limits current and ignites the arc, and the classic solution is a magnetic leakage transformer: a transformer whose magnetic circuit is deliberately shunted so that its leakage inductance performs the ballast function. Unlike an electronic ballast, this approach has no semiconductors to fail, which is why it is still standard in water disinfection and industrial curing.

For buyers, the specification is a set of lamp parameters and a set of thermal realities, not a conventional transformer datasheet.

Load Characteristics

UV lamp types and ballast implications
Lamp type Typical power Ignition voltage Ballast character
Low pressure mercury (germicidal) 10–320 W 500–1,500 V Leakage transformer or electronic; high reactance to limit arc current
Amalgam low pressure 80–1,000 W Higher ignition; temperature sensitive Leakage transformer with defined short-circuit current
Medium pressure mercury 1–20 kW 1–3 kV Leakage transformer, often with a series capacitor

The lamp is a negative-resistance load: after ignition, its voltage falls as current rises, so the ballast must present enough series impedance to stabilize the arc. In a leakage transformer, that impedance is set by the magnetic shunt geometry, which means the mechanical design of the shunt determines the electrical behaviour.

What the Design Controls

Thermal Reality

A leakage transformer runs hot by design: the leakage flux dissipates in the shunt and nearby laminations. Losses are not concentrated where a conventional core would put them, and hot spots can appear at the shunt rather than in the winding. Practical consequences: specify Class H insulation, verify the shunt temperature during the type test, and expect the ballast to be the hottest magnetic component in a UV reactor cabinet.

In water disinfection cabinets, the ballast often sits next to the UV reactor, which is itself warm. Combined ambient of 50–60 °C is common; a part rated for 40 °C ambient will not survive there.

Safety and Insulation

Ignition voltages of 1–3 kV require the same care as any high-voltage transformer: layer insulation, end-of-winding grading, and hipot at a level well above the ignition voltage. Where the lamp circuit is accessible (some curing installations), the creepage and clearance must be treated as a high-voltage circuit, and the output should be treated as non-SELV.

What to Specify

  1. Lamp type, power, arc voltage, and ignition voltage requirement.
  2. Required short-circuit current and lamp operating current, with tolerance.
  3. Mains voltage range and frequency, including the lowest voltage for ignition.
  4. Ambient at the installation, including proximity to the reactor.
  5. Insulation class, hipot level, and the ignition-voltage test method.
  6. Mechanical envelope, mounting, and whether the shunt is adjustable.

Related reading

We build leakage transformers for UV disinfection and curing with controlled shunt geometry, measured short-circuit current, and Class H insulation, and we test ignition voltage at the low mains limit. Send your lamp data and cabinet ambient to sales@sirui-tech.com and the Magnetic Core team will size the shunt and the winding together.