Rules of Thumb That Hide the Physics

Every magnetics engineer has heard “4 A per mm² for natural cooling, 6 for forced”. The numbers are useful starting points and dangerous when treated as limits, because the permitted current density is an outcome of the thermal design, not a property of the wire. Two windings at the same 5 A/mm² can run 25 K apart if one is potted to a cold plate and the other sits in a sealed box.

What Actually Limits a Winding

A Workable Selection Method

Current density starting points by cooling condition
Cooling Starting density (A/mm²) What must then be checked
Free air, small part (<50 cm² surface) 3.5–4.5 Rise by resistance change at worst-case ambient
Free air, large part 2.0–3.0 Hot spot inside the winding; thermal resistance estimate
Forced air 1–2 m/s 5–7 Airflow actually reaching the part, not the enclosure rating
Potted to a metal surface 6–9 Interface material, flatness, and the potting layer thickness
Liquid cooled cold plate 8–12 Coolant temperature, PD and the CTE stress on the winding

The method is: pick a starting density, compute the loss, compute the rise with the actual thermal resistance, then check whether the result respects the insulation class margin. If it does not, reduce the density, add copper, or improve the thermal path — in that order of cost.

Frequency Changes the Answer

At 50/60 Hz the winding is essentially DC and the density rules above apply directly. Above roughly 20 kHz the AC resistance factor becomes the dominant term: a winding at 4 A/mm² with Fr = 2.0 dissipates like one at 5.7 A/mm² at DC. The fix is construction, not wire size: fewer layers, interleaving to reduce the magnetomotive force between layers, Litz or foil where the current is high.

What to Put on the Drawing

  1. Wire diameter and insulation grade, with the strand construction if Litz.
  2. Permitted temperature rise and the measurement method.
  3. Maximum fill factor or the maximum winding build height, since this constrains the supplier’s choices.
  4. Whether the part will be potted or varnished, because it changes the thermal path.
  5. Any handling constraint, such as a minimum wire diameter for production reliability.